Maretron RIM100 Run Indicator Module
Maretron RIM100 Run Indicator Module — Product description
Maretron's Run Indicator Module monitors both AC and DC electrical circuits and reports, over an NMEA 2000 network, whether or not the electrical circuit is energized and running. The RIM100 works equally as well for monitoring manually switched loads (e.g., running lights, anchor lights, or deck lights) as it does for automatically switched loads.
Monitoring automatically switched loads (e.g., bilge pumps, engine exhaust/intake fans, and transfer pumps) via the RIM100 is especially useful because you know exactly when equipment is, or isn't running.
RIM100 Run Indicator Module
Part #: RIM100-01
Maretron's Run Indicator Module monitors both AC and DC electrical circuits and reports, over an NMEA 2000 network, whether or not the electrical circuit is energized and running. The RIM100 works equally as well for monitoring manually switched loads (running lights, anchor lights, or deck lights) as it does for automatically switched loads. Monitoring automatically switched loads (bilge pumps, engine exhaust/intake fans, and transfer pumps) via the RIM100 is especially useful because you know exactly when equipment is, or isn't running.
Features:
- Monitors and reports the running status of connected devices
- Works with both AC and DC loads
- Works with both automatically and manually switched loads
- Can indicate the status of a wide variety of loads: Bilge bumps, Winches, Running lights, Transfer pumps, Exhaust/intake fans
Maretron's operation indicator module can monitor AC and DC circuits, and report whether the circuit is powered on and whether...
- Monitors and reports the running status of connected devices
- Works with both AC and DC loads
- Works with both automatically and manually switched loads
- Can indicate the status of a wide variety of loads: Bilge Pumps, Winches, Running Lights, Transfer Pumps, Exhaust/Intake Fans
- Monitors fuel and detects presence of water in fuel
- Includes built in timers and counters so you know how long and many times a load is energized
Electrical:
- Number of Channels: 6
- “OFF†Voltage Range (DC): 0VDC-1VDC
- “OFF†Voltage Range (AC): 0VAC-1VAC RMS
- “ON†Voltage Range (DC): 9VDC to 240VDC
- “ON†Voltage Range (AC): 9VAC to 240VAC (RMS)
- Operating Voltage: 9 to 32 Volts (DC Voltage)
- Power Consumption: 100 mA NMEA 2000 Interface
- Load Equivalence Number (LEN): 2 (NMEA 2000 Spec. [1LEN = 50 mA])
- Reverse Battery Protection: Yes (Indefinitely)
- Load Dump Protection: Yes (Energy Rated per SAE J1113)
SKU: NVN-34158
MPN: RIM100-01
UPC: 873804000206
Technical specifications
| Brand | Maretron |
| Model | Maretron RIM100 Run Indicator Module |
| SKU / MFR# | 34158 |
Set product metafields under specs.* to populate this table.
Frequently asked questions