Go Power F-400 Class-T 400 Amp Slow Blow Inverter Fuse
Go Power F-400 Class-T 400 Amp Slow Blow Inverter Fuse — Product description
The Go Power F-400 is a 400 amp Class T slow blow fuse built for high-current inverter installs. It's the replacement fuse Go Power makes for its own inverter fuse blocks, with the DC interrupt rating a 12V bank feeding a 3000 watt inverter actually needs. Slow blow so it rides through startup surge, and fast enough to clear a real short before it does damage.
The Go Power F-400 is the 400 amp Class T slow blow fuse that guards the main DC feed between your battery bank and a Go Power inverter. It's the single most important piece of protection in a high-current inverter install, and it's the one people skip until they've seen what a shorted 4/0 cable can do. This is the replacement fuse Go Power builds for its own inverter fuse blocks, so it drops in clean and carries the interrupt rating those big DC circuits actually need.
Why Class T? Because an inverter running 2000 to 3000 watts pulls serious amperage off a 12V bank, and a dead short at the battery can dump thousands of amps before anything reacts. A Class T fuse is built for exactly that. It's a DC-rated semiconductor fuse with a very high interrupt capacity, so when something goes wrong it clears the fault fast and terminates power for good instead of arcing across the gap. That's the whole job. Protect the cable, protect the boat, protect you.
The slow blow part matters too. Inverters don't sip power, they surge. Fire up a 3000 watt unit and the soft-start inrush can spike well past the steady-state draw for a moment. A slow blow characteristic rides through that startup surge without nuisance-tripping, then still opens hard on a real fault. So you get a fuse that leaves you alone during normal operation and drops the hammer when it counts.
This 400 amp rating is the top of Go Power's Class T line, which runs from 110 up to 400 amps. It's sized for the bigger inverters, the 3000 watt class and similar high-draw setups. The fuse works across 12, 24, 32, and 48 volt battery systems, so it fits everything from a simple 12V house bank to a larger 48V setup, as long as you've sized your cable to the load.
Speaking of cable, this is where installs go wrong. A 400 amp fuse belongs on a 400 amp circuit. Pair it with heavy cable, 4/0 AWG is the common call on the battery-to-inverter run, and keep the run as short as you reasonably can. Undersized wire on a long run heats up, and that heat migrates into the fuse body and the lugs. Do it right and the fuse runs cool and boring, which is exactly what you want from a fuse.
Mounting is simple but not casual. Put the fuse as close to the battery positive as you can, within a few inches, so it's protecting the whole cable run and not just the far end. Use a proper marine-rated fuse block or holder, torque the lugs to spec, and check them again after the first few weeks. Loose connections are the number one cause of melted terminals on high-current DC. Pick a dry, accessible spot, keep it up out of the bilge, and mount it so you can actually get a wrench on it if you ever need to swap the fuse.
Who's this for? Anyone running a Go Power inverter big enough to need 400 amp protection, on a boat or an RV. If you're building out a 12V house bank to run AC loads underway or at anchor, this is the fuse that sits between a good day and a very bad one. It's a spare worth keeping aboard, too. A blown main fuse with no replacement on the shelf means no inverter until the next chandlery, so a lot of owners keep one in the spares kit.
One honest note: this is the fuse only. If you don't already have a Go Power fuse block to seat it in, you'll want the matching block as well. And if a fuse blows, don't just drop another one in and walk away. A Class T fuse doesn't nuisance-trip. If it opened, something caused it, and it's worth finding the short or the overload before you power back up.
Key Features
- Class T construction with high DC interrupt capacity, built to clear a dead short at the battery before it damages cable or gear
- 400 amp rating, the top of Go Power's Class T line, sized for 3000 watt class inverters and other high-draw DC loads
- Slow blow characteristic rides through inverter soft-start surge without nuisance tripping
- DC-rated semiconductor fuse made specifically for inverter circuits
- Works across 12, 24, 32, and 48 volt battery systems
- Drop-in replacement fuse for Go Power inverter fuse blocks
- Terminates power completely when it blows, with no arcing across the gap
Why Buy from NVN Marine
- Authorized Go Power reseller, full manufacturer warranty
- NMEA member and ABYC certified, advice from real boat techs
- Same-day shipping before 3 PM ET on in-stock items
- NY headquarters and Fort Lauderdale flagship retail store
Technical specifications
| Title | Go Power! F-400 Class-T 400 Amp Slow Blow Inverter Fuse |
|---|---|
| Brand | Go Power |
| Manufacturer Part Number | F-400 |
| UPC | 839085000311 |
| Fuse Type | Class T |
| Amperage Rating | 400 Amp |
| Blow Characteristic | Slow Blow |
| Circuit Type | DC |
| Application | Inverter DC circuit protection |
| Compatible Battery Systems | 12V, 24V, 32V, 48V |
| Designed For | Go Power inverters |
| Replacement For | Go Power inverter fuse blocks |
| Fuse Line Range | 110 to 400 Amp Class T |
Frequently asked questions
What is a Class T slow blow fuse?
It's a DC-rated fuse with a very high interrupt capacity, built to clear the huge fault currents a battery bank can push during a short. The slow blow part means it rides through the brief inrush surge when an inverter starts up, then still opens hard on a real fault.
Will the F-400 work on 24 volt and 48 volt inverter systems?
Yes. Go Power rates this fuse for 12, 24, 32, and 48 volt battery systems. Just make sure your cable is sized for the actual load on your setup.
Does this fuse come with a fuse block?
No, this is the fuse only. It's designed to seat in a Go Power inverter fuse block, so you'll need the matching block if you don't already have one.
How close to the battery should I mount the fuse?
As close to the battery positive as you can manage, within a few inches. That way the fuse protects the entire cable run, not just the far end.
What cable size should I pair with a 400 amp fuse?
A 400 amp circuit calls for heavy cable, and 4/0 AWG is the common choice on the battery-to-inverter run. Undersized wire on a long run overheats and pushes that heat into the fuse body.
Will a slow blow fuse trip when my inverter starts up?
It shouldn't. The slow blow characteristic is designed to ride through the soft-start inrush that 2000 to 3000 watt inverters produce, so you get protection without nuisance blows.
What inverters is the F-400 made for?
It's built for Go Power inverters that need 400 amp protection, typically the larger 3000 watt class units running off a 12 volt house bank.
My fuse blew. Can I just replace it and keep going?
Replace it, yes, but find the cause first. A Class T fuse doesn't nuisance-trip. If it opened, there was a real short or overload, and you want to fix that before you power the inverter back up.
Can I mount this fuse in the bilge or engine room?
Pick a dry, accessible spot and keep it up out of the bilge where it won't sit in water. Use a marine-rated holder, torque the lugs to spec, and recheck them after the first few weeks.