{"product_id":"egis-a-series-50a-ac-dc-panel-circuit-breaker","title":"Egis A Series 50A Single-Pole AC\/DC Circuit Breaker","description":"\u003cp class=\"nvn-hero\"\u003eThe Egis A Series 50-amp breaker protects a single AC or DC circuit right from your boat's panel. It's a magnetic-hydraulic breaker with a toggle that doubles as a switch, a 5kA interrupt rating for big battery banks, and stainless self-locking hardware. UL 1077 listed and backed by a 4-year warranty.\u003c\/p\u003e\n\n\u003cdiv class=\"nvn-description\"\u003e\n\u003cp\u003eThe Egis A Series toggle circuit breaker gives you a clean, panel-mount way to protect a single 50-amp circuit on your boat. It's rated for both AC and DC, so the same breaker works whether you're guarding a shore-power run or a heavy DC feed off the battery bank.\u003c\/p\u003e\n\u003cp\u003eThis is a magnetic-hydraulic breaker in the A Series body, and it drops into any standard panel cut for A-Series or C-Series breakers. Mounting screws come in the box. The toggle doubles as an on\/off switch, which is handy when you want to kill a circuit without pulling a fuse. Stainless steel self-locking hardware keeps the terminals tight through years of vibration and temperature swings.\u003c\/p\u003e\n\u003cp\u003eWhere it earns its keep is the interrupt rating. At 5kA on AC and 1.5kA on DC, it can safely clear a fault on a circuit tied to a big paralleled battery bank, the kind of setup that can dump a lot of current in a hurry. It's UL 1077 listed, rated for 6,000 cycles at full load, and backed by a 4-year warranty.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"nvn-features\"\u003e\n  \u003cli\u003e50 amp continuous rating across AC and DC, 277 Vac \/ 80 Vdc max, so one breaker covers shore-power and battery circuits\u003c\/li\u003e\n  \u003cli\u003e5kA \/ 277Vac and 1.5kA \/ 80Vdc interrupt capacity safely clears faults on large paralleled battery banks\u003c\/li\u003e\n  \u003cli\u003eMagnetic-hydraulic design with a toggle that doubles as an on\/off switch for the circuit\u003c\/li\u003e\n  \u003cli\u003eMounts in standard panels cut for A-Series and C-Series breakers, mounting screws included\u003c\/li\u003e\n  \u003cli\u003eStainless steel self-locking hardware holds connections tight through vibration, UL 1077 listed and 4-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"nvn-trust\"\u003e\n  \u003ch2\u003eWhy Buy from NVN Marine\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eAuthorized Egis Mobile Electronics reseller, full manufacturer warranty\u003c\/li\u003e\n    \u003cli\u003eNMEA member and ABYC certified, advice from real boat techs\u003c\/li\u003e\n    \u003cli\u003eSame-day shipping before 3 PM ET on in-stock items\u003c\/li\u003e\n    \u003cli\u003eNY headquarters and Fort Lauderdale flagship retail store\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"nvn-faq\"\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eCan I use this breaker on both AC and DC circuits?\u003c\/summary\u003e\n    \u003cp\u003eYes. It's rated for both, up to 277 Vac and 80 Vdc, so the same breaker works on a shore-power run or a DC feed off the battery bank.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat panels does it fit?\u003c\/summary\u003e\n    \u003cp\u003eIt mounts in any standard panel cut for A-Series or C-Series magnetic-hydraulic circuit breakers. Mounting screws are included in the box.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eIs this a single-pole or double-pole breaker?\u003c\/summary\u003e\n    \u003cp\u003eSingle pole. It protects one circuit at a 50-amp continuous rating.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat's the interrupt capacity, and why does it matter?\u003c\/summary\u003e\n    \u003cp\u003e5kA at 277Vac and 1.5kA at 80Vdc. That high rating lets it safely clear a fault on a circuit tied to a large paralleled battery bank, which can dump a lot of current fast.\u003c\/p\u003e\n  \u003c\/details\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"nvn-specs\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003cth\u003eTitle\u003c\/th\u003e\n\u003ctd\u003eEGIS A Series Black Toggle Panel Mount Circuit Breaker Single Pole AC\/DC 50 Amp Retail Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eEgis Mobile Electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e3211-50\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e850067590989\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eA Series\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003ePole Configuration\u003c\/th\u003e\n\u003ctd\u003eSingle Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eContinuous Current\u003c\/th\u003e\n\u003ctd\u003e50 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMax Voltage\u003c\/th\u003e\n\u003ctd\u003e277 Vac \/ 80 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eInterrupt Capacity\u003c\/th\u003e\n\u003ctd\u003e5kA \/ 277Vac, 1.5kA \/ 80 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eElectrical Endurance\u003c\/th\u003e\n\u003ctd\u003e6,000 Cycles @ Rated Current\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eRegulatory Compliance\u003c\/th\u003e\n\u003ctd\u003eUL 1077\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMounting Type\u003c\/th\u003e\n\u003ctd\u003ePanel Mount (Toggle)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eHardware\u003c\/th\u003e\n\u003ctd\u003eStainless Steel Self-Locking\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e4 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr class=\"nvn-doc\"\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.22 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr class=\"nvn-doc\"\u003e\n\u003cth\u003ePackage Dimensions (L x W x H)\u003c\/th\u003e\n\u003ctd\u003e3.5 x 3.5 x 2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr class=\"nvn-doc\"\u003e\n\u003cth\u003eProduct Brochure\u003c\/th\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/114335BR.pdf\" target=\"_blank\" rel=\"noopener nofollow\"\u003eDownload PDF\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Can I use this breaker on both AC and DC circuits?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Yes. It's rated for both, up to 277 Vac and 80 Vdc, so the same breaker works on a shore-power run or a DC feed off the battery bank.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What panels does it fit?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It mounts in any standard panel cut for A-Series or C-Series magnetic-hydraulic circuit breakers. Mounting screws are included in the box.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Is this a single-pole or double-pole breaker?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Single pole. It protects one circuit at a 50-amp continuous rating.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What's the interrupt capacity, and why does it matter?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"5kA at 277Vac and 1.5kA at 80Vdc. That high rating lets it safely clear a fault on a circuit tied to a large paralleled battery bank, which can dump a lot of current fast.\"\n            }\n        }\n    ]\n}\n\u003c\/script\u003e\n","brand":"Egis Mobile Electric","offers":[{"title":"Default Title","offer_id":67647914442845,"sku":"1004740","price":13.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0299\/7266\/0317\/files\/114335XL.jpg?v=1795105730","url":"https:\/\/nvnmarine.com\/products\/egis-a-series-50a-ac-dc-panel-circuit-breaker","provider":"NVN Marine","version":"1.0","type":"link"}