{"product_id":"coleman-mach-compressor-relay-1460-1131-rv-a-c-part","title":"Coleman Mach Compressor Relay 1460-1131 for RV Air Conditioners","description":"\u003cp class=\"nvn-hero\"\u003eThe Coleman compressor relay 1460-1131 is the OEM switch that powers your Mach rooftop air conditioner's compressor when the thermostat calls for cooling. If your fan runs but the AC won't get cold, this is usually the part to replace. Fits Mach models 6535, 6536, 6537, 6538, 6636, 6795, and 46515.\u003c\/p\u003e\n\n\u003cdiv class=\"nvn-description\"\u003e\n\u003cp\u003eThis is the OEM Coleman compressor relay, part number 1460-1131, for Mach rooftop air conditioners. It's the small but critical switch that sends power to your compressor when the thermostat calls for cooling. When it goes bad, your AC fan keeps spinning but the compressor never kicks on, so you get air movement without any cold air. If that sounds like what you're dealing with, this is usually the part that fixes it.\u003c\/p\u003e\n\u003cp\u003eThe relay fits a specific list of Coleman Mach models: 6535, 6536, 6537, 6538, 6636, 6795, and 46515. Check the model number on the label inside your unit or on the shroud before you order, because Coleman uses different relays across the lineup and this one is matched to those units. Getting the right part the first time saves you a second trip up the ladder.\u003c\/p\u003e\n\u003cp\u003eA failing compressor relay is one of the more common reasons a rooftop unit stops cooling, and it's an easy fix if you're comfortable working around 120-volt AC. You'll shut off power at the breaker and the RV disconnect, pull the interior ceiling grille, and swap the old relay for this one. It's a quick job for a technician and very doable for a hands-on owner who respects the electrical side. If you're not sure, have an RV tech handle it. There's real voltage up there.\u003c\/p\u003e\n\u003cp\u003eBecause this is a genuine Coleman replacement part, it drops right into the factory wiring without adapters or guesswork. Same terminals, same rating, same fit. That matters on a rooftop AC, where heat and vibration are hard on electrical components and a mismatched relay can fail early or damage the compressor. We keep these on the shelf for the summer rush, when a dead AC in the middle of a trip is the last thing you want.\u003c\/p\u003e\n\u003cp\u003eNot sure this is your problem? A relay that's failed often shows a burnt smell, pitted contacts, or a compressor that hums and trips instead of starting. Those are the classic signs. If your unit won't power on at all, that's usually somewhere else in the system, and we're happy to help you sort it out before you buy.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"nvn-features\"\u003e\n  \u003cli\u003eOEM Coleman part number 1460-1131, a direct factory replacement compressor relay\u003c\/li\u003e\n  \u003cli\u003eFits Coleman Mach models 6535, 6536, 6537, 6538, 6636, 6795, and 46515\u003c\/li\u003e\n  \u003cli\u003eSwitches power to the AC compressor when the thermostat calls for cooling\u003c\/li\u003e\n  \u003cli\u003eDrops into the factory wiring with no adapters or rewiring\u003c\/li\u003e\n  \u003cli\u003eCommon fix for a unit that runs the fan but won't cool\u003c\/li\u003e\n  \u003cli\u003eGenuine Coleman RVP replacement built for rooftop heat and vibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"nvn-trust\"\u003e\n  \u003ch2\u003eWhy Buy from NVN Marine\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eAuthorized Coleman reseller, full manufacturer warranty\u003c\/li\u003e\n    \u003cli\u003eNMEA member and ABYC certified, advice from real boat techs\u003c\/li\u003e\n    \u003cli\u003eSame-day shipping before 3 PM ET on in-stock items\u003c\/li\u003e\n    \u003cli\u003eNY headquarters and Fort Lauderdale flagship retail store\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"nvn-faq\"\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eHow do I know which Coleman Mach model I have?\u003c\/summary\u003e\n    \u003cp\u003eYour model number is on a label inside the unit, usually visible when you remove the interior ceiling grille, and often on the shroud up on the roof. Match that number to this relay's fit list: 6535, 6536, 6537, 6538, 6636, 6795, or 46515.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat does the compressor relay do?\u003c\/summary\u003e\n    \u003cp\u003eIt's the switch that sends power to the compressor when the thermostat calls for cooling. If it fails, the fan still runs but the compressor won't start, so you get air with no cooling.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWill this fit my air conditioner?\u003c\/summary\u003e\n    \u003cp\u003eIt fits Coleman Mach models 6535, 6536, 6537, 6538, 6636, 6795, and 46515. Check your model number before ordering, since Coleman uses different relays across the lineup.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eIs this a genuine Coleman part?\u003c\/summary\u003e\n    \u003cp\u003eYes. This is the OEM Coleman replacement, part number 1460-1131, so it matches the factory terminals, rating, and fit.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eHow can I tell the relay has failed?\u003c\/summary\u003e\n    \u003cp\u003eCommon signs are a fan that runs while the compressor stays silent, a burnt smell, or a compressor that hums and trips instead of starting.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eCan I replace it myself?\u003c\/summary\u003e\n    \u003cp\u003eIf you're comfortable working around 120-volt AC, yes. Shut off power at the breaker and the RV disconnect first. If you're unsure, have an RV technician do it.\u003c\/p\u003e\n  \u003c\/details\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"nvn-specs\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003cth\u003eTitle\u003c\/th\u003e\n\u003ctd\u003eColeman Mach Compressor Relay 1460-1131\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eColeman\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eColeman RVP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e1460-1131\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e755790407217\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003ePart Type\u003c\/th\u003e\n\u003ctd\u003eCompressor Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eRV Rooftop Air Conditioner\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eCompatible Coleman Mach Models\u003c\/th\u003e\n\u003ctd\u003e6535, 6536, 6537, 6538, 6636, 6795, 46515\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How do I know which Coleman Mach model I have?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Your model number is on a label inside the unit, usually visible when you remove the interior ceiling grille, and often on the shroud up on the roof. Match that number to this relay's fit list: 6535, 6536, 6537, 6538, 6636, 6795, or 46515.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What does the compressor relay do?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It's the switch that sends power to the compressor when the thermostat calls for cooling. If it fails, the fan still runs but the compressor won't start, so you get air with no cooling.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Will this fit my air conditioner?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It fits Coleman Mach models 6535, 6536, 6537, 6538, 6636, 6795, and 46515. Check your model number before ordering, since Coleman uses different relays across the lineup.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Is this a genuine Coleman part?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Yes. This is the OEM Coleman replacement, part number 1460-1131, so it matches the factory terminals, rating, and fit.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How can I tell the relay has failed?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Common signs are a fan that runs while the compressor stays silent, a burnt smell, or a compressor that hums and trips instead of starting.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Can I replace it myself?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"If you're comfortable working around 120-volt AC, yes. Shut off power at the breaker and the RV disconnect first. If you're unsure, have an RV technician do it.\"\n            }\n        }\n    ]\n}\n\u003c\/script\u003e\n","brand":"Coleman","offers":[{"title":"Default Title","offer_id":45074110218333,"sku":"2009470","price":32.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0299\/7266\/0317\/files\/s-l1600_7.webp?v=1790624855","url":"https:\/\/nvnmarine.com\/products\/coleman-mach-compressor-relay-1460-1131-rv-a-c-part","provider":"NVN Marine","version":"1.0","type":"link"}