{"product_id":"coleman-1499-5471-run-capacitor-7-5-mfd-370v-ac","title":"Coleman 1499-5471 Run Capacitor, 7.5 MFD 370 VAC","description":"\u003cp class=\"nvn-hero\"\u003eThis is the genuine Coleman replacement run capacitor, part 1499-5471, rated 7.5 MFD at 370 volts AC. It's the part that keeps your Coleman RV air conditioner's motor turning smoothly, and a weak one is a common cause of slow fans, hard starts, and tripped breakers. A quick, affordable fix to get you blowing cold again.\u003c\/p\u003e\n\n\u003cdiv class=\"nvn-description\"\u003e\n\u003cp\u003eIf your Coleman air conditioner is struggling to start, humming without spinning up, or the fan and compressor just won't come to full speed, a tired run capacitor is one of the first things we check. This is the factory replacement, Coleman part 1499-5471, rated at 7.5 MFD and 370 volts AC. It's the same run capacitor that keeps the motor turning smoothly once the unit is running.\u003c\/p\u003e\n\u003cp\u003eA run capacitor does exactly what the name says. It stores and releases a charge on every cycle to keep the AC motor turning efficiently. When it weakens, you'll often see the classic symptoms: the unit trips a breaker, the fan turns slowly, or the compressor tries to start and then quits. Swapping in a fresh capacitor with the correct rating is usually a quick fix, and it's a lot cheaper than a service call or a new air conditioner.\u003c\/p\u003e\n\u003cp\u003eHere's the part that matters most. The capacitance has to match. This one is 7.5 MFD, so it replaces a 7.5 MFD capacitor, not a 5 or a 10. The voltage rating, 370 VAC, is a maximum, so you never want to go below it. Match the numbers to what came out of your unit and you're good.\u003c\/p\u003e\n\u003cp\u003eReplacing it isn't complicated, but it does deserve respect. A capacitor can hold a charge even after the power is off, so kill the breaker, disconnect shore power, and discharge the old cap before you touch the terminals. If you're not comfortable working around AC voltage, have an RV tech handle it. Ten minutes of caution beats a nasty surprise.\u003c\/p\u003e\n\u003cp\u003eThis capacitor is built for Coleman air conditioners. If you're not sure it's the right one for your model, pull your existing capacitor and check the printed rating against 7.5 MFD, 370 VAC before you order. Match those two numbers and the physical terminal style, and you'll have your AC blowing cold again in no time.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"nvn-features\"\u003e\n  \u003cli\u003e7.5 MFD capacitance, matched to Coleman air conditioners that call for a 7.5 microfarad run capacitor\u003c\/li\u003e\n  \u003cli\u003e370 volts AC rating, sized for the working voltage of RV rooftop and ducted air conditioner motors\u003c\/li\u003e\n  \u003cli\u003eRun capacitor design keeps the fan and compressor motor turning smoothly once the unit is running\u003c\/li\u003e\n  \u003cli\u003eGenuine Coleman replacement, part 1499-5471, a direct swap for the original capacitor\u003c\/li\u003e\n  \u003cli\u003eCommon cure for slow fans, hard starts, and breaker trips caused by a weak capacitor\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"nvn-trust\"\u003e\n  \u003ch2\u003eWhy Buy from NVN Marine\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eAuthorized Coleman reseller, full manufacturer warranty\u003c\/li\u003e\n    \u003cli\u003eNMEA member and ABYC certified, advice from real boat techs\u003c\/li\u003e\n    \u003cli\u003eSame-day shipping before 3 PM ET on in-stock items\u003c\/li\u003e\n    \u003cli\u003eNY headquarters and Fort Lauderdale flagship retail store\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"nvn-faq\"\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat does the Coleman 1499-5471 capacitor do?\u003c\/summary\u003e\n    \u003cp\u003eIt's a run capacitor for your Coleman air conditioner. It stores and releases charge on every cycle to keep the fan and compressor motor turning smoothly once the unit is up and running. When it weakens, the motor loses efficiency and can struggle to start.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eCan I use a 7.5 MFD capacitor in place of a 5 MFD?\u003c\/summary\u003e\n    \u003cp\u003eNo. The capacitance has to match what your unit was built for. This capacitor is 7.5 MFD, so use it to replace a 7.5 MFD capacitor, not a 5 MFD. Substituting a different microfarad rating can overload or underdrive the motor. Check the rating printed on your old capacitor before ordering.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eCan I use a capacitor with a higher voltage rating?\u003c\/summary\u003e\n    \u003cp\u003eThe 370 VAC rating is a maximum working voltage, so a higher voltage rating is fine as a replacement, but never go lower. The capacitance in MFD is the number that has to match exactly. Match both to what came out of your unit.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eIs this a run capacitor or a start capacitor?\u003c\/summary\u003e\n    \u003cp\u003eIt's a run capacitor, rated 7.5 MFD at 370 volts AC. Run capacitors stay in the circuit the whole time the motor is running, unlike a start capacitor that only kicks in briefly at startup.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eHow do I know if my capacitor has failed?\u003c\/summary\u003e\n    \u003cp\u003eCommon signs are a fan that turns slowly or not at all, a compressor that hums but won't start, or a breaker that trips when the AC kicks on. A bulged or leaking top is a dead giveaway. If you have a multimeter with a capacitance setting, you can test the old one against its printed rating.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eIs it safe to replace the capacitor myself?\u003c\/summary\u003e\n    \u003cp\u003eIt can be, but a capacitor holds a charge even after the power is off. Kill the breaker, disconnect shore power, and discharge the old capacitor before touching the terminals. If you're not comfortable working around AC voltage, have an RV tech do it.\u003c\/p\u003e\n  \u003c\/details\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"nvn-specs\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003cth\u003eTitle\u003c\/th\u003e\n\u003ctd\u003eColeman 1499-5471 Run Capacitor, 7.5 MFD 370 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eColeman\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eColeman RVP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e1499-5471\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e755790406111\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eCapacitor Type\u003c\/th\u003e\n\u003ctd\u003eRun Capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eCapacitance\u003c\/th\u003e\n\u003ctd\u003e7.5 MFD\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd\u003e370 Volts AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eColeman air conditioners\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What does the Coleman 1499-5471 capacitor do?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It's a run capacitor for your Coleman air conditioner. It stores and releases charge on every cycle to keep the fan and compressor motor turning smoothly once the unit is up and running. When it weakens, the motor loses efficiency and can struggle to start.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Can I use a 7.5 MFD capacitor in place of a 5 MFD?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"No. The capacitance has to match what your unit was built for. This capacitor is 7.5 MFD, so use it to replace a 7.5 MFD capacitor, not a 5 MFD. Substituting a different microfarad rating can overload or underdrive the motor. Check the rating printed on your old capacitor before ordering.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Can I use a capacitor with a higher voltage rating?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The 370 VAC rating is a maximum working voltage, so a higher voltage rating is fine as a replacement, but never go lower. The capacitance in MFD is the number that has to match exactly. Match both to what came out of your unit.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Is this a run capacitor or a start capacitor?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It's a run capacitor, rated 7.5 MFD at 370 volts AC. Run capacitors stay in the circuit the whole time the motor is running, unlike a start capacitor that only kicks in briefly at startup.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How do I know if my capacitor has failed?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Common signs are a fan that turns slowly or not at all, a compressor that hums but won't start, or a breaker that trips when the AC kicks on. A bulged or leaking top is a dead giveaway. If you have a multimeter with a capacitance setting, you can test the old one against its printed rating.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Is it safe to replace the capacitor myself?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It can be, but a capacitor holds a charge even after the power is off. Kill the breaker, disconnect shore power, and discharge the old capacitor before touching the terminals. If you're not comfortable working around AC voltage, have an RV tech do it.\"\n            }\n        }\n    ]\n}\n\u003c\/script\u003e\n","brand":"Coleman","offers":[{"title":"Default Title","offer_id":45079586439261,"sku":"2010002","price":21.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0299\/7266\/0317\/files\/ImageServerAPI_f8c81a4b-324c-477e-a9b3-5c0b7334baf3.webp?v=1790613312","url":"https:\/\/nvnmarine.com\/products\/coleman-1499-5471-run-capacitor-7-5-mfd-370v-ac","provider":"NVN Marine","version":"1.0","type":"link"}