{"product_id":"blue-sea-7564-bss-100a-ac-double-pole-breaker","title":"Blue Sea C-Series Flat Rocker Double Pole 100A AC Breaker","description":"\u003cp class=\"nvn-hero\"\u003eThe Blue Sea 7564-BSS is a 100A AC double pole flat rocker breaker built for 120\/240 volt main protection. It's magnetic hydraulic and trip free, with 5,000 ampere interrupt capacity to meet ABYC requirements. A solid pick for the head of your shore power or inverter circuit.\u003c\/p\u003e\n\n\u003cdiv class=\"nvn-description\"\u003e\n\u003cp\u003eSome breakers are just a switch you hope never trips. The Blue Sea C-Series Flat Rocker Double Pole 100A AC is the opposite. It's a protection device first, and a switch second, built to sit at the head of your shore power or inverter circuit and do its job quietly for years. Model 7564-BSS is the 100 amp double pole version, rated for 120 and 240 volt AC.\u003c\/p\u003e\n\u003cp\u003eThe headline feature is the 5,000 ampere interrupt capacity. That's the number that meets ABYC requirements for 120\/240 volt main protection, and it's why this breaker is a common choice as an AC main. Wired as a 120 volt main, the double pole design switches both the hot and the neutral at once. One flip of the rocker and the whole circuit is dead. That's exactly what you want when you're working behind a panel with the boat plugged in.\u003c\/p\u003e\n\u003cp\u003eIt's a magnetic hydraulic breaker, and it's trip free. Trip free means you can't hold the rocker in the ON position during a fault. If the breaker senses a fault, it trips, period. And since it's a double pole unit, it trips all poles if any one pole trips. You won't end up with a half-live circuit after an overload. Nobody wants to troubleshoot that at the dock.\u003c\/p\u003e\n\u003cp\u003eThe flat rocker actuator is the other thing boaters notice. It sits flush when the breaker is ON, which looks clean in a panel and makes it easy to see at a glance what's live. It's also a good fit for a main breaker you'll want to flip deliberately, not bump by accident while reaching past it.\u003c\/p\u003e\n\u003cp\u003eWiring is straightforward for anyone who's terminated heavy AC cable before. The terminal studs are 1\/4-20 tin-plated brass, and the spec calls for 35 in-lb (3.95 Nm) of torque on them. Don't skip the torque wrench on a 100 amp connection. A loose lug on a main breaker is a heat problem waiting to happen. The breaker itself mounts with 6-32 stainless steel screws, torqued to 6 in-lb (0.68 Nm), so go easy and don't crank them down.\u003c\/p\u003e\n\u003cp\u003eOperating range runs from -40 deg C to 85 deg C, which covers an unheated engine room in a northern winter and a closed-up boat sitting in a Fort Lauderdale summer. The breaker is rated for 10,000 switching cycles. For a main you'll flip a few times a season, that's more than you'll ever use.\u003c\/p\u003e\n\u003cp\u003eWhere does it belong? Think of the spot between your shore power inlet and the rest of the AC system, or ahead of an inverter circuit that carries real load. On a boat with a 120 volt main, this is the breaker that lets you shut everything down from one place. When we talk boaters through AC upgrades, the main is usually the part they want done right the first time. Pair it with correctly sized cable and properly crimped lugs, and the whole run stays cool and quiet.\u003c\/p\u003e\n\u003cp\u003eA few things to check before you order. This is the double pole version, so it fits a 120 volt main where you switch hot and neutral. If you're protecting a 240 volt system and want to switch both hots and the neutral, the triple pole version is the one that does that, and it's a separate part. Confirm the amperage against your cable gauge and your shore power inlet, and match the breaker to the circuit, not the other way around. If you're not sure, send us your panel layout and we'll help you sort it out.\u003c\/p\u003e\n\u003cp\u003eWe're an authorized Blue Sea Systems reseller, so you get the full manufacturer warranty. It weighs 0.64 lb (0.29 kg), so it won't add noticeable load to a panel. Order one, wire it in, torque it right, and forget about it. That's how a main breaker should work.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"nvn-features\"\u003e\n  \u003cli\u003e100A AC double pole rating, so one flip kills both hot and neutral on a 120 volt main\u003c\/li\u003e\n  \u003cli\u003e5,000 ampere interrupt capacity to meet ABYC requirements for 120\/240 volt main protection\u003c\/li\u003e\n  \u003cli\u003eMagnetic hydraulic, trip free design, so it can't be held ON during a fault\u003c\/li\u003e\n  \u003cli\u003eTrips all poles if any one pole trips, so you never end up with a half-live circuit\u003c\/li\u003e\n  \u003cli\u003eFlat rocker actuator sits flush when ON for a clean panel and a quick visual check\u003c\/li\u003e\n  \u003cli\u003e1\/4-20 tin-plated brass terminal studs for solid, corrosion resistant connections\u003c\/li\u003e\n  \u003cli\u003e6-32 stainless steel mounting screws that stand up to the boat environment\u003c\/li\u003e\n  \u003cli\u003eRated for 10,000 switching cycles and -40 to 85 deg C operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"nvn-trust\"\u003e\n  \u003ch2\u003eWhy Buy from NVN Marine\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eAuthorized Blue Sea Systems reseller, full manufacturer warranty\u003c\/li\u003e\n    \u003cli\u003eNMEA member and ABYC certified, advice from real boat techs\u003c\/li\u003e\n    \u003cli\u003eSame-day shipping before 3 PM ET on in-stock items\u003c\/li\u003e\n    \u003cli\u003eNY headquarters and Fort Lauderdale flagship retail store\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"nvn-faq\"\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat is the amp rating on the Blue Sea 7564-BSS?\u003c\/summary\u003e\n    \u003cp\u003eIt's rated 100A AC. This is a double pole C-Series Flat Rocker breaker with a flat rocker actuator.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat voltage is the 7564-BSS rated for?\u003c\/summary\u003e\n    \u003cp\u003eMaximum voltage is 120V AC \/ 240V AC. As a double pole unit it can serve as a 120 volt AC main circuit breaker, switching both hot and neutral.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eCan I use this as a main breaker for 240 volt service?\u003c\/summary\u003e\n    \u003cp\u003eThe double pole is described for use as a 120 volt AC main. The triple pole version is the one described for a 240 volt main that switches both hots and the neutral. It's a separate part.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat is the interrupt capacity?\u003c\/summary\u003e\n    \u003cp\u003e5,000 ampere interrupt capacity, which meets ABYC requirements for 120\/240 volt main protection. The spec sheet lists it as 5000A @ 48V DC.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat type of circuit breaker is it?\u003c\/summary\u003e\n    \u003cp\u003eIt's a magnetic hydraulic, trip free breaker. The 'trip free' design means it can't be held ON during a fault current condition.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eIf one pole trips, what happens to the other?\u003c\/summary\u003e\n    \u003cp\u003eThe breaker trips all poles if any one pole trips, so the whole circuit shuts down together.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat size are the terminal studs and what torque do they need?\u003c\/summary\u003e\n    \u003cp\u003eThe terminal studs are 1\/4-20 tin-plated brass. Torque them to 35 in-lb (3.95 Nm).\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eHow is the breaker mounted?\u003c\/summary\u003e\n    \u003cp\u003eIt mounts with 6-32 stainless steel screws. Torque for the mounting screws is 6 in-lb (0.68 Nm).\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat temperatures can it handle?\u003c\/summary\u003e\n    \u003cp\u003eMinimum operating temperature is -40 deg C and maximum is 85 deg C.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eHow many times can it be switched?\u003c\/summary\u003e\n    \u003cp\u003eIt's rated for 10,000 switching cycles.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eHow much does it weigh?\u003c\/summary\u003e\n    \u003cp\u003e0.64 lb (0.29 kg).\u003c\/p\u003e\n  \u003c\/details\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"nvn-specs\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003cth\u003eTitle\u003c\/th\u003e\n\u003ctd\u003eBlue Sea C-Series Flat Rocker Circuit Breaker Double Pole 100A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eBlue Sea Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e7564-BSS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e632085075644\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eAmperage\u003c\/th\u003e\n\u003ctd\u003e100A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eActuator Style\u003c\/th\u003e\n\u003ctd\u003eFlat Rocker\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMaximum Voltage\u003c\/th\u003e\n\u003ctd\u003e120V AC \/ 240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eCircuit Breaker Type\u003c\/th\u003e\n\u003ctd\u003eMagnetic Hydraulic, trip free\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eInterrupt Capacity\u003c\/th\u003e\n\u003ctd\u003e5000A @ 48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eTerminal Stud\u003c\/th\u003e\n\u003ctd\u003e1\/4-20 Tin-Plated Brass\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eTerminal Stud Torque\u003c\/th\u003e\n\u003ctd\u003e35 in-lb (3.95 Nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMounting Screw\u003c\/th\u003e\n\u003ctd\u003e6-32 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMounting Screw Torque\u003c\/th\u003e\n\u003ctd\u003e6 in-lb (0.68 Nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMinimum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e-40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMaximum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eSwitching Cycles\u003c\/th\u003e\n\u003ctd\u003e10000\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.64 lb (0.29 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What is the amp rating on the Blue Sea 7564-BSS?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It's rated 100A AC. This is a double pole C-Series Flat Rocker breaker with a flat rocker actuator.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What voltage is the 7564-BSS rated for?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Maximum voltage is 120V AC \/ 240V AC. As a double pole unit it can serve as a 120 volt AC main circuit breaker, switching both hot and neutral.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Can I use this as a main breaker for 240 volt service?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The double pole is described for use as a 120 volt AC main. The triple pole version is the one described for a 240 volt main that switches both hots and the neutral. It's a separate part.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What is the interrupt capacity?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"5,000 ampere interrupt capacity, which meets ABYC requirements for 120\/240 volt main protection. The spec sheet lists it as 5000A @ 48V DC.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What type of circuit breaker is it?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It's a magnetic hydraulic, trip free breaker. The 'trip free' design means it can't be held ON during a fault current condition.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"If one pole trips, what happens to the other?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The breaker trips all poles if any one pole trips, so the whole circuit shuts down together.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What size are the terminal studs and what torque do they need?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The terminal studs are 1\/4-20 tin-plated brass. Torque them to 35 in-lb (3.95 Nm).\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How is the breaker mounted?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It mounts with 6-32 stainless steel screws. Torque for the mounting screws is 6 in-lb (0.68 Nm).\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What temperatures can it handle?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Minimum operating temperature is -40 deg C and maximum is 85 deg C.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How many times can it be switched?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It's rated for 10,000 switching cycles.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How much does it weigh?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"0.64 lb (0.29 kg).\"\n            }\n        }\n    ]\n}\n\u003c\/script\u003e\n","brand":"Blue Sea Systems","offers":[{"title":"Default Title","offer_id":68065181532253,"sku":"1004911","price":79.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0299\/7266\/0317\/files\/BSS7564_001.jpg?v=1795080314","url":"https:\/\/nvnmarine.com\/products\/blue-sea-7564-bss-100a-ac-double-pole-breaker","provider":"NVN Marine","version":"1.0","type":"link"}