{"product_id":"blue-sea-7563-bss-80a-ac-double-pole-breaker","title":"Blue Sea C-Series Flat Rocker Breaker, Double Pole 80A AC","description":"\u003cp class=\"nvn-hero\"\u003eThe Blue Sea Systems C-Series Flat Rocker Circuit Breaker is a double pole, 80A AC breaker for 120V or 240V AC circuits. It's trip free, trips all poles together, and works as a 120 volt AC main to switch both hot and neutral. A solid choice for boat AC panels.\u003c\/p\u003e\n\n\u003cdiv class=\"nvn-description\"\u003e\n\u003cp\u003eThe Blue Sea Systems C-Series Flat Rocker Circuit Breaker, Double Pole, 80A AC (model 7563-BSS) protects and switches an AC circuit in a single part. It's a magnetic hydraulic breaker rated for 80 amps AC at up to 120V or 240V AC, with two poles ganged together. If you're building or refreshing the AC side of your boat's electrical system, this is the kind of breaker that sits at the head of the panel and quietly does the heavy lifting.\u003c\/p\u003e\n\u003cp\u003eLet's talk about why two poles matter. Blue Sea describes this breaker as usable for 120 volt AC main protection, switching both the hot and the neutral. On a boat that's a real benefit. When you open the breaker, you're not leaving a live conductor connected on the far side of the switch. And because the poles are linked, the breaker will trip all poles if any one pole trips. You don't end up with half a circuit still energized after a fault.\u003c\/p\u003e\n\u003cp\u003eThe trip mechanism is magnetic hydraulic, and it's a trip free design. In plain terms, you can't hold the rocker in the ON position while a fault current is present. The breaker is going to open no matter how hard somebody leans on it. That's exactly what you want from main protection on a boat where shore power, a generator or an inverter feeds the panel. The listed interrupt capacity is 5,000 amperes, which Blue Sea states meets ABYC requirements for 120\/240 volt main protection. If you're working toward an ABYC-compliant AC system, that number is worth knowing before you order.\u003c\/p\u003e\n\u003cp\u003eNow the hardware. The terminal studs are 1\/4-20 tin-plated brass, and the stud torque is 35 in-lb (3.95 Nm). Tin plating helps with corrosion where the salt air gets in, but it doesn't replace good crimps and heat-shrink on your ring terminals. Use a torque wrench and snug each lug to spec. Loose connections on an 80 amp circuit make heat, and heat is the thing you really don't want behind a panel. The breaker mounts with 6-32 stainless steel screws at 6 in-lb (0.68 Nm), so there's no need to lean on them.\u003c\/p\u003e\n\u003cp\u003eIt's a flat rocker style. The rocker sits flush with the panel face when it's ON, so it's a clean look at the helm or in the electrical locker, and it's harder to bump by accident than a protruding toggle. The operating temperature range runs from -40 deg C to 85 deg C, and the breaker is rated for 10,000 switching cycles. It weighs 0.64 lb (0.29 kg), so it won't add much to a panel build.\u003c\/p\u003e\n\u003cp\u003eA few things to check before you buy. This is the AC version, so match it to an AC circuit and don't treat it as a general-purpose DC part. Confirm your wire gauge is sized for an 80 amp load, and confirm the breaker's rating fits the circuit it's protecting. We don't have panel cutout dimensions in our data, so check the manufacturer's mounting drawing before you cut or drill. And if you're unsure how a double pole breaker fits into your shore power setup, call the crew and we'll talk it through with you.\u003c\/p\u003e\n\u003cp\u003eKeep the part number handy when you're shopping or matching up an existing panel. This one is 7563-BSS, the double pole 80A AC version in the C-Series flat rocker line. Blue Sea also makes single pole versions, and they aren't interchangeable with this one for a double pole job, so double check the pole count against your wiring diagram before you order.\u003c\/p\u003e\n\u003cp\u003eBottom line? It's a no-nonsense, two pole 80 amp AC breaker with a trip free mechanism and a published spec sheet you can actually design around. If you're replacing a tired main or laying out a new AC panel, it's an easy one to wire in.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"nvn-features\"\u003e\n  \u003cli\u003e80A AC rating at up to 120V \/ 240V AC, sized for main protection on a boat's AC system.\u003c\/li\u003e\n  \u003cli\u003eDouble pole design switches both hot and neutral when used as a 120V AC main.\u003c\/li\u003e\n  \u003cli\u003eTrips all poles if any one pole trips, so a fault doesn't leave half the circuit live.\u003c\/li\u003e\n  \u003cli\u003eTrip free magnetic hydraulic mechanism can't be held ON during a fault current.\u003c\/li\u003e\n  \u003cli\u003e5,000 ampere interrupt capacity to meet ABYC requirements for 120\/240 volt main protection.\u003c\/li\u003e\n  \u003cli\u003e1\/4-20 tin-plated brass terminal studs, torqued to 35 in-lb (3.95 Nm).\u003c\/li\u003e\n  \u003cli\u003eFlat rocker actuator for a clean look at the panel.\u003c\/li\u003e\n  \u003cli\u003e6-32 stainless steel mounting screws, torqued to 6 in-lb (0.68 Nm).\u003c\/li\u003e\n  \u003cli\u003eRated for 10,000 switching cycles from -40 deg C to 85 deg C.\u003c\/li\u003e\n  \u003cli\u003eCompact 0.64 lb (0.29 kg) body that's easy to handle during a panel build.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"nvn-trust\"\u003e\n  \u003ch2\u003eWhy Buy from NVN Marine\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eAuthorized Blue Sea Systems reseller, full manufacturer warranty\u003c\/li\u003e\n    \u003cli\u003eNMEA member and ABYC certified, advice from real boat techs\u003c\/li\u003e\n    \u003cli\u003eSame-day shipping before 3 PM ET on in-stock items\u003c\/li\u003e\n    \u003cli\u003eNY headquarters and Fort Lauderdale flagship retail store\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"nvn-faq\"\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat is the amp rating of the Blue Sea 7563-BSS?\u003c\/summary\u003e\n    \u003cp\u003eIt's an 80A AC breaker with a maximum voltage of 120V AC \/ 240V AC. It has two poles.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eCan I use this as a 120 volt AC main breaker?\u003c\/summary\u003e\n    \u003cp\u003eYes. Blue Sea states the double pole version can be used as a 120 volt AC main circuit breaker to switch hot and neutral.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat happens if one pole trips?\u003c\/summary\u003e\n    \u003cp\u003eThe breaker will trip all poles if any one pole trips. The poles are linked, so the whole breaker opens.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat does trip free mean?\u003c\/summary\u003e\n    \u003cp\u003eIt means the breaker can't be held ON during a fault current condition. If a fault happens, it opens even if someone is holding the rocker.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat type of circuit breaker is this?\u003c\/summary\u003e\n    \u003cp\u003eIt's a magnetic hydraulic breaker with a flat rocker actuator.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat size are the terminal studs and what torque should I use?\u003c\/summary\u003e\n    \u003cp\u003eThe terminal studs are 1\/4-20 tin-plated brass. Torque them to 35 in-lb (3.95 Nm).\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eHow do I mount it?\u003c\/summary\u003e\n    \u003cp\u003eIt uses 6-32 stainless steel mounting screws torqued to 6 in-lb (0.68 Nm). We don't list a panel cutout size, so check the manufacturer's mounting drawing before you cut.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat is the interrupt capacity?\u003c\/summary\u003e\n    \u003cp\u003eBlue Sea lists 5,000 ampere interrupt capacity to meet ABYC requirements for 120\/240 volt main protection. The spec sheet shows 5000A @ 48V DC.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat temperatures can it handle?\u003c\/summary\u003e\n    \u003cp\u003eThe listed operating range is -40 deg C to 85 deg C.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eHow many switching cycles is it rated for?\u003c\/summary\u003e\n    \u003cp\u003e10,000 switching cycles.\u003c\/p\u003e\n  \u003c\/details\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"nvn-specs\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003cth\u003eTitle\u003c\/th\u003e\n\u003ctd\u003eBlue Sea C-Series Flat Rocker Circuit Breaker Double Pole 80A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eBlue Sea Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e7563-BSS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e632085075637\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eAmperage\u003c\/th\u003e\n\u003ctd\u003e80A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eActuator Style\u003c\/th\u003e\n\u003ctd\u003eFlat Rocker\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMaximum Voltage\u003c\/th\u003e\n\u003ctd\u003e120V AC \/ 240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eCircuit Breaker Type\u003c\/th\u003e\n\u003ctd\u003eMagnetic Hydraulic - trip free\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eTerminal Stud\u003c\/th\u003e\n\u003ctd\u003e1\/4-20 Tin-Plated Brass\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eTerminal Stud Torque\u003c\/th\u003e\n\u003ctd\u003e35 in-lb (3.95 Nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eInterrupt Capacity\u003c\/th\u003e\n\u003ctd\u003e5000A @ 48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMinimum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e-40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMaximum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMounting Screw\u003c\/th\u003e\n\u003ctd\u003e6-32 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMounting Screw Torque\u003c\/th\u003e\n\u003ctd\u003e6 in-lb (0.68 Nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eSwitching Cycles\u003c\/th\u003e\n\u003ctd\u003e10000\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.64 lb (0.29 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What is the amp rating of the Blue Sea 7563-BSS?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It's an 80A AC breaker with a maximum voltage of 120V AC \/ 240V AC. It has two poles.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Can I use this as a 120 volt AC main breaker?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Yes. Blue Sea states the double pole version can be used as a 120 volt AC main circuit breaker to switch hot and neutral.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What happens if one pole trips?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The breaker will trip all poles if any one pole trips. The poles are linked, so the whole breaker opens.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What does trip free mean?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It means the breaker can't be held ON during a fault current condition. If a fault happens, it opens even if someone is holding the rocker.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What type of circuit breaker is this?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It's a magnetic hydraulic breaker with a flat rocker actuator.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What size are the terminal studs and what torque should I use?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The terminal studs are 1\/4-20 tin-plated brass. Torque them to 35 in-lb (3.95 Nm).\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How do I mount it?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It uses 6-32 stainless steel mounting screws torqued to 6 in-lb (0.68 Nm). We don't list a panel cutout size, so check the manufacturer's mounting drawing before you cut.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What is the interrupt capacity?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Blue Sea lists 5,000 ampere interrupt capacity to meet ABYC requirements for 120\/240 volt main protection. The spec sheet shows 5000A @ 48V DC.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What temperatures can it handle?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The listed operating range is -40 deg C to 85 deg C.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How many switching cycles is it rated for?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"10,000 switching cycles.\"\n            }\n        }\n    ]\n}\n\u003c\/script\u003e\n","brand":"Blue Sea Systems","offers":[{"title":"Default Title","offer_id":68065217282141,"sku":"1004912","price":79.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0299\/7266\/0317\/files\/BSS7563_001.jpg?v=1795081317","url":"https:\/\/nvnmarine.com\/products\/blue-sea-7563-bss-80a-ac-double-pole-breaker","provider":"NVN Marine","version":"1.0","type":"link"}