{"product_id":"blue-sea-7561-bss-50a-ac-double-pole-breaker","title":"Blue Sea 7561-BSS C-Series Flat Rocker Breaker, 50A AC DP","description":"\u003cp class=\"nvn-hero\"\u003eThe Blue Sea Systems 7561-BSS is a C-Series flat rocker circuit breaker, double pole, rated 50A AC. It's a magnetic hydraulic, trip free breaker that switches and protects at the same time, so you can use it as a 120 volt AC main without adding a separate switch.\u003c\/p\u003e\n\n\u003cdiv class=\"nvn-description\"\u003e\n\u003cp\u003eIf you've ever stood in a dim engine compartment tracing a dead shore power line, you already know why the main AC breaker matters. The Blue Sea Systems 7561-BSS is a C-Series Flat Rocker double pole circuit breaker rated 50A AC. It does two jobs in one box. It's a manual switch you can flip to kill the circuit, and it's the protection that opens the line when something goes wrong. That's one less part to buy, mount, and wire.\u003c\/p\u003e\n\u003cp\u003eThe double pole layout is the point of this breaker. Two poles means it switches two conductors at the same time. On a 120 volt AC system, that lets you use it as the main breaker to switch both the hot and the neutral. Either pole sensing a fault trips the whole breaker, so you don't end up with one leg still live while the other has dropped out. Blue Sea Systems lists it for 120 volt AC and 240 volt AC maximum voltage, and the 50 amp rating suits a main feed on a boat with a 50 amp shore power inlet wired the way your panel calls for.\u003c\/p\u003e\n\u003cp\u003eThen there's the trip mechanism. This is a magnetic hydraulic breaker with a trip free design. That phrase sounds like marketing, but it's a real safety feature. Trip free means you can't hold the handle in the ON position while a fault current is flowing. Somebody can lean on the rocker as hard as they like and the breaker will still open. On a boat, where the person flipping the switch might be wet, tired, and standing on a moving deck, we like that a lot.\u003c\/p\u003e\n\u003cp\u003eThe actuator is a flat rocker. It sits flush when the breaker is ON, which keeps the face of your panel tidy and makes it harder to bump a handle sticking out into a walkway or a locker. Flat rockers also read clearly at a glance, so you can tell the state of a circuit from across the cabin.\u003c\/p\u003e\n\u003cp\u003eWiring is straightforward. Terminals are 1\/4-20 tin-plated brass studs, and the spec calls for 35 in-lb (3.95 Nm) of torque on them. Tin plating on brass is a sensible choice around salt air, though it's no excuse to skip proper terminals and a dry, ventilated install spot. Don't skimp on that torque value either. A loose lug on a 50 amp circuit heats up, and heat on a boat is the last thing you want behind a panel. Use a real torque driver or at least a good feel for 35 in-lb, and check the connection again after the first few weeks of use.\u003c\/p\u003e\n\u003cp\u003eMounting uses 6-32 stainless steel screws, torqued to 6 in-lb (0.68 Nm). That's snug, not cranked down. Over-tightening small screws into a panel is an easy way to strip something or crack a surround. Stainless holds up well to damp conditions, and the low torque figure is worth respecting.\u003c\/p\u003e\n\u003cp\u003eOn the numbers, the interrupt capacity is listed as 5,000 amperes, and the distributor notes this meets ABYC requirements for 120\/240 volt, 50 ampere main protection. The spec sheet shows the figure as 5000A @ 48V DC. It's rated for operation from -40 deg C up to 85 deg C, which covers a cold lake in the off season and a sealed compartment on a hot July afternoon. Switching life is listed at 10000 cycles, so ordinary use as an on\/off switch won't wear it out in a hurry. It weighs 0.64 lb (0.29 kg).\u003c\/p\u003e\n\u003cp\u003eWho's it for? Anyone building or refitting an AC panel who needs a 50 amp double pole main. That might be a cruiser with a pair of shore power cords feeding a main distribution panel, or a project boat where the old breaker finally gave up. It's also a good fit when you're replacing a breaker that tripped so often it stopped inspiring confidence. Match the amperage to the wire gauge and the load you've got. This breaker protects the circuit, but it can't fix an undersized conductor.\u003c\/p\u003e\n\u003cp\u003eA couple of honest notes. This is the double pole version, so it switches two lines. The distributor's description mentions that a triple pole version can be used as a 240 volt AC main to switch both hots and the neutral. If your system calls for that, confirm what your panel layout needs before you order. And as always with AC work, if you're not comfortable inside the panel, bring in a marine electrician. Shore power can hurt you, and it isn't worth guessing.\u003c\/p\u003e\n\u003cp\u003eWe're an authorized Blue Sea Systems reseller, so you're getting genuine gear with the manufacturer's warranty. If you're not sure whether the 7561-BSS fits your panel, send us a note with your boat and your current setup, and our crew will help you sort it out.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"nvn-features\"\u003e\n  \u003cli\u003e50A AC rating on a double pole breaker, so one device protects and switches both conductors of a 120 volt main.\u003c\/li\u003e\n  \u003cli\u003eDouble pole design trips all poles if any one pole trips, so one leg never stays live by itself.\u003c\/li\u003e\n  \u003cli\u003eMagnetic hydraulic, trip free mechanism. The handle can't be held ON during a fault current condition.\u003c\/li\u003e\n  \u003cli\u003e5,000 ampere interrupt capacity to meet ABYC requirements for 120\/240 volt, 50 ampere main protection.\u003c\/li\u003e\n  \u003cli\u003eFlat rocker actuator sits flush when ON, keeping the panel face clean and the handle out of harm's way.\u003c\/li\u003e\n  \u003cli\u003e1\/4-20 tin-plated brass terminal studs, torqued to 35 in-lb (3.95 Nm).\u003c\/li\u003e\n  \u003cli\u003eOperating range of -40 deg C to 85 deg C for cold-weather storage and hot compartments.\u003c\/li\u003e\n  \u003cli\u003e10000 switching cycles, so it holds up as a regular on\/off switch.\u003c\/li\u003e\n  \u003cli\u003e6-32 stainless steel mounting screws, torqued to 6 in-lb (0.68 Nm).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"nvn-trust\"\u003e\n  \u003ch2\u003eWhy Buy from NVN Marine\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eAuthorized Blue Sea Systems reseller, full manufacturer warranty\u003c\/li\u003e\n    \u003cli\u003eNMEA member and ABYC certified, advice from real boat techs\u003c\/li\u003e\n    \u003cli\u003eSame-day shipping before 3 PM ET on in-stock items\u003c\/li\u003e\n    \u003cli\u003eNY headquarters and Fort Lauderdale flagship retail store\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"nvn-faq\"\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eIs the Blue Sea 7561-BSS a double pole breaker?\u003c\/summary\u003e\n    \u003cp\u003eYes. It has 2 poles, and it trips all poles if any one pole trips.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eCan I use it as a 120 volt AC main breaker?\u003c\/summary\u003e\n    \u003cp\u003eYes. The distributor lists the double pole version as usable as a 120 volt AC main circuit breaker to switch hot and neutral.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eIs it rated for 240 volts?\u003c\/summary\u003e\n    \u003cp\u003eThe maximum voltage is listed as 120V AC \/ 240V AC. For a 240 volt AC main that switches both hots and the neutral, the distributor points to a triple pole version, so check your panel layout first.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat does trip free mean?\u003c\/summary\u003e\n    \u003cp\u003eIt means the breaker can't be held in the ON position during a fault current condition. If a fault occurs, it opens even if someone is pushing on the handle.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat's the interrupt capacity?\u003c\/summary\u003e\n    \u003cp\u003eThe distributor lists 5,000 ampere interrupt capacity to meet ABYC requirements for 120\/240 volt, 50 ampere main protection. The spec table shows it as 5000A @ 48V DC.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat size terminals does it use and how tight should they be?\u003c\/summary\u003e\n    \u003cp\u003eIt has 1\/4-20 tin-plated brass terminal studs. The terminal stud torque is 35 in-lb (3.95 Nm).\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat screws mount it and what's the torque?\u003c\/summary\u003e\n    \u003cp\u003eIt mounts with 6-32 stainless steel screws, torqued to 6 in-lb (0.68 Nm).\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat temperatures can it handle?\u003c\/summary\u003e\n    \u003cp\u003eThe listed operating range is -40 deg C minimum to 85 deg C maximum.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eHow many times can it be switched?\u003c\/summary\u003e\n    \u003cp\u003eThe switching cycle rating is 10000.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat type of breaker is it?\u003c\/summary\u003e\n    \u003cp\u003eIt's a magnetic hydraulic, trip free circuit breaker with a flat rocker actuator.\u003c\/p\u003e\n  \u003c\/details\u003e\n  \u003cdetails\u003e\n    \u003csummary\u003eHow much does it weigh?\u003c\/summary\u003e\n    \u003cp\u003eIt weighs 0.64 lb (0.29 kg).\u003c\/p\u003e\n  \u003c\/details\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"nvn-specs\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003cth\u003eTitle\u003c\/th\u003e\n\u003ctd\u003eBlue Sea C-Series Flat Rocker Circuit Breaker Double Pole 50A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eBlue Sea Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e7561-BSS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e632085075613\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eAmperage\u003c\/th\u003e\n\u003ctd\u003e50A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eActuator Style\u003c\/th\u003e\n\u003ctd\u003eFlat Rocker\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMaximum Voltage\u003c\/th\u003e\n\u003ctd\u003e120V AC \/ 240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eCircuit Breaker Type\u003c\/th\u003e\n\u003ctd\u003eMagnetic Hydraulic - trip free\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eTerminal Stud\u003c\/th\u003e\n\u003ctd\u003e1\/4-20 Tin-Plated Brass\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eTerminal Stud Torque\u003c\/th\u003e\n\u003ctd\u003e35 in-lb (3.95 Nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eInterrupt Capacity\u003c\/th\u003e\n\u003ctd\u003e5000A @ 48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMinimum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e-40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMaximum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMounting Screw\u003c\/th\u003e\n\u003ctd\u003e6-32 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eMounting Screw Torque\u003c\/th\u003e\n\u003ctd\u003e6 in-lb (0.68 Nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eSwitching Cycles\u003c\/th\u003e\n\u003ctd\u003e10000\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.64lb (0.29 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Is the Blue Sea 7561-BSS a double pole breaker?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Yes. It has 2 poles, and it trips all poles if any one pole trips.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Can I use it as a 120 volt AC main breaker?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Yes. The distributor lists the double pole version as usable as a 120 volt AC main circuit breaker to switch hot and neutral.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Is it rated for 240 volts?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The maximum voltage is listed as 120V AC \/ 240V AC. For a 240 volt AC main that switches both hots and the neutral, the distributor points to a triple pole version, so check your panel layout first.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What does trip free mean?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It means the breaker can't be held in the ON position during a fault current condition. If a fault occurs, it opens even if someone is pushing on the handle.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What's the interrupt capacity?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The distributor lists 5,000 ampere interrupt capacity to meet ABYC requirements for 120\/240 volt, 50 ampere main protection. The spec table shows it as 5000A @ 48V DC.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What size terminals does it use and how tight should they be?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It has 1\/4-20 tin-plated brass terminal studs. The terminal stud torque is 35 in-lb (3.95 Nm).\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What screws mount it and what's the torque?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It mounts with 6-32 stainless steel screws, torqued to 6 in-lb (0.68 Nm).\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What temperatures can it handle?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The listed operating range is -40 deg C minimum to 85 deg C maximum.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How many times can it be switched?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The switching cycle rating is 10000.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What type of breaker is it?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It's a magnetic hydraulic, trip free circuit breaker with a flat rocker actuator.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How much does it weigh?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"It weighs 0.64 lb (0.29 kg).\"\n            }\n        }\n    ]\n}\n\u003c\/script\u003e\n","brand":"Blue Sea Systems","offers":[{"title":"Default Title","offer_id":68065166557277,"sku":"1004905","price":79.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0299\/7266\/0317\/files\/BSS7561_001.jpg?v=1795079540","url":"https:\/\/nvnmarine.com\/products\/blue-sea-7561-bss-50a-ac-double-pole-breaker","provider":"NVN Marine","version":"1.0","type":"link"}