Victron MIDI-Fuse 60A/58V-M6 (Package of 5)
MIDI-Fuse 60A/58V-M6 (Package of 5)Victron Energy's MIDI fuses are essentially a smaller version of the MEGA fuses and are known to have low voltage drop and cold resistance....
Victron Energy fuse blocks and fuses protect battery banks, inverters and high-current DC circuits. Find ANL, MEGA and CNN fuses plus matching holders sized for 12, 24 and 48 volt systems. Choosing Victron Fuse Blocks and Fuses Start with the fuse type your gear calls for. Victron uses ANL, MEGA and CNN fuses for different products, and a Lynx shunt or an inverter will specify the type and rating it needs. Match the fuse type to the holder, since an ANL fuse will not seat in a MEGA holder. Size the amp rating to the circuit. The fuse protects the wire and the device, so pick a rating above normal draw but below the wire ampacity. Check the voltage rating...
MIDI-Fuse 60A/58V-M6 (Package of 5)Victron Energy's MIDI fuses are essentially a smaller version of the MEGA fuses and are known to have low voltage drop and cold resistance....
MEGA Fuse 40A/80V (Package of 5 Pieces)Victron Energy supplies a range of fuse holders and fuses to suit a wide range of installations, and the MEGA fuses are...
MEGA Fuse 200A/80V (Package of 5 Pieces)Victron Energy supplies a range of fuse holders and fuses to suit a wide range of installations, and the MEGA fuses are...
MEGA Fuse 60A/80V (Package of 5 Pieces)Victron Energy supplies a range of fuse holders and fuses to suit a wide range of installations, and the MEGA fuses are...
ANL-Fuse 400A/80V for 48V Products (Package of 5)Victron Energy's ANL fuses are bolt-down fast-acting and have a higher short-circuit breaking capability than MEGA fuses. This particular pack of...
MEGA-Fuse 150A/80V Ceramic (Package of 5 Pieces)Victron Energy supplies a range of fuse holders and fuses to suit a wide range of installations, and the MEGA fuses are...
MEGA-Fuse 125A/80V Ceramic (Package of 5 Pieces)Victron Energy supplies a range of fuse holders and fuses to suit a wide range of installations, and the MEGA fuses are...
ANL-Fuse 300A/80V for 48V Products (Package of 5)Victron Energy's ANL fuses are bolt-down fast-acting and have a higher short-circuit breaking capability than MEGA fuses. This particular pack of...
Fuse Holder for ANL-FuseThis Victron fuse holder is for ANL fuses. Please note that this fuse holder doesn’t have a cover.Features:2 terminal studsPlease contact your dealer for any...
ANL-Fuse 500A/80V for 48V Products (Package of 1)Victron Energy's ANL fuses are bolt-down fast-acting fuses and have a higher short-circuit breaking capability than MEGA fuses. This particular package...
ANL-Fuse 400A/80V for 48V Products (Package of 1)Victron Energy's ANL fuses are bolt-down fast-acting fuses and have a higher short-circuit breaking capability than MEGA fuses. This particular package...
ANL-Fuse 300A/80V for 48V Products (Package of 1)Victron Energy's ANL fuses are bolt-down fast-acting fuses and have a higher short-circuit breaking capability than MEGA fuses. This particular package...
MIDI-Fuse 100A/58V for 48V Products (Package of 1)Victron Energy's MIDI fuses are essentially a smaller version of the MEGA fuses and are known to have low voltage drop...
MIDI-Fuse 80A/58V for 48V Products (Package of 1)Victron Energy's MIDI fuses are essentially a smaller version of the MEGA fuses and are known to have low voltage drop...
MIDI-Fuse 60A/58V for 48V Products (Package of 1)Victron Energy's MIDI fuses are essentially a smaller version of the MEGA fuses and are known to have low voltage drop...
MIDI-Fuse 50A/58V for 48V Products (Package of 1)Victron Energy's MIDI fuses are essentially a smaller version of the MEGA fuses and are known to have low voltage drop...
MIDI-Fuse 40A/58V for 48V Products (Package of 1)Victron Energy's MIDI fuses are essentially a smaller version of the MEGA fuses and are known to have low voltage drop...
MIDI-Fuse 30A/58V for 48V Products (Package of 1)Victron Energy's MIDI fuses are essentially a smaller version of the MEGA fuses and are known to have low voltage drop...
MIDI-Fuse 150A/32V (Package of 5)Victron Energy's MIDI fuses are essentially a smaller version of the MEGA fuses and are known to have low voltage drop and cold resistance....
MIDI-Fuse 125A/32V (Package of 5)Victron Energy's MIDI fuses are essentially a smaller version of the MEGA fuses and are known to have low voltage drop and cold resistance....
MIDI-Fuse 60A/32V (Package of 5)Victron Energy's MIDI fuses are essentially a smaller version of the MEGA fuses and are known to have low voltage drop and cold resistance....
MEGA-Fuse 300A/58V for 48V Products (Package of 1)Victron Energy's MEGA fuses are frequently used in Victron Energy DC distribution systems. This particular package contains ONE Victron MEGA 300...
MEGA-Fuse 250A/58V for 48V Products (Package of 1)Victron Energy's MEGA fuses are frequently used in Victron Energy DC distribution systems. This particular package contains ONE Victron MEGA 250...
MEGA-Fuse 200A/58V for 48V Products (Package of 1)Victron Energy's MEGA fuses are frequently used in Victron Energy DC distribution systems. This particular package contains ONE Victron MEGA 200...
Victron Energy fuse blocks and fuses protect battery banks, inverters and high-current DC circuits. Find ANL, MEGA and CNN fuses plus matching holders sized for 12, 24 and 48 volt systems.
Start with the fuse type your gear calls for. Victron uses ANL, MEGA and CNN fuses for different products, and a Lynx shunt or an inverter will specify the type and rating it needs. Match the fuse type to the holder, since an ANL fuse will not seat in a MEGA holder.
Size the amp rating to the circuit. The fuse protects the wire and the device, so pick a rating above normal draw but below the wire ampacity. Check the voltage rating too, since 48-volt systems need fuses rated for that voltage, and Victron lists 80-volt-rated fuses for 48-volt banks. Multi-way holders with a busbar tidy several circuits in one place. Confirm the type, amp and voltage rating against your system before ordering.
It depends on your Victron gear. ANL, MEGA and CNN are used for different products, so check what the device or shunt specifies.
Pick a rating above the circuit normal draw but below the wire ampacity, so the fuse protects both the wire and the device.
Yes. Use fuses rated for the system voltage. Victron lists 80-volt-rated fuses suited to 48-volt battery banks.