Blue Sea C-Series Flat Rocker Breaker 7565-BSS Triple Pole 50A AC — Product description

The Blue Sea Systems C-Series Flat Rocker Circuit Breaker (7565-BSS) is a triple pole, 50A AC breaker for 120/240 volt shore power mains. It's trip free, carries a 5,000 amp interrupt rating and opens both hot lines and the neutral together. A solid pick for 50 amp boats.

If your boat has a 50 amp shore inlet, the main AC breaker is the part that decides what happens when something goes wrong behind it. This Blue Sea Systems C-Series Flat Rocker Triple Pole breaker (7565-BSS) is built for that job. It's rated 50A AC, handles 120V AC and 240V AC, and opens all three poles together, so both hot lines and the neutral get cut at once.

That triple pole layout matters. On a 240 volt system, the three poles let you switch both lines (the hots) and the neutral with a single handle. And if you're wiring a 120 volt main instead, the double pole version of this breaker is the match for that setup. This one is the triple, so it fits the 240 volt main position. Check your panel layout and shore power setup before you order so the pole count lines up with what you're feeding.

The internals are magnetic hydraulic, and the design is trip free. In plain terms, you can't hold the handle ON against a fault. If the breaker trips, it opens and stays open no matter what you do with the handle. To reset it, push the handle fully OFF first, then back ON. Plenty of boaters think a tripped breaker is broken the first time it happens. It isn't. That's just how a trip free design behaves.

Interrupt capacity is 5,000 amps, which is the number ABYC looks for on 120/240 volt, 50 amp main protection. The operating temperature range runs from -40 deg C to 85 deg C, so a cold engine room in February and a hot one in July are both covered. It's rated for 10,000 switching cycles, which is a lot of flips for a part that mostly sits there waiting.

Wiring is straightforward. The terminal studs are 1/4-20 tin-plated brass, and they want 35 in-lb of torque (3.95 Nm). Don't guess on that number. Under-torqued lugs are the classic cause of a warm terminal, and a warm terminal on a 50 amp feed is something you want to catch before it becomes a bigger problem. Use a real torque driver, snug the connection, then recheck it after the first few heat cycles. Land the shore inlet on the line side and the panel bus on the load side.

The flat rocker actuator sits flush with the faceplate when it's ON, which gives you a clean look at the helm or in the electrical panel. Mounting is with 6-32 stainless steel screws, torqued to 6 in-lb (0.68 Nm). That's gentle. These are small screws in a plastic body, so go easy and don't crank them down. Also note the flat rocker cutout is its own shape. Make sure your panel is cut for flat rocker breakers before you commit, because forcing a different cutout style usually ends in frustration.

This is an AC breaker, and it's marked 50A AC for a reason. C-Series AC and DC breakers can look a lot alike on the shelf, so read the label. A DC rated breaker on shore power is the wrong trip device. If you're replacing a breaker in an existing panel, match the amperage, the voltage rating, the pole count and the actuator style. Four checks, and you'll avoid most of the returns we see on breakers.

If this breaker keeps tripping right after you close it, take the trip seriously. A magnetic hydraulic breaker has a built in delay that rides through normal inrush from things like a battery charger or inverter. When it opens again immediately, assume there's a real fault somewhere downstream. That could be a shorted water heater element, a failed pump, or a chafed conductor. Upsizing the breaker won't fix it and it can turn a nuisance into a hazard.

Weight is only 0.93 lb (0.42 kg), so it won't add anything noticeable to a loaded panel. It's a good fit for mid-size and larger cruisers, sportfish boats and trawlers with a 50 amp service. It also suits anyone rebuilding an AC panel who wants matching Blue Sea Systems C-Series breakers across the branch circuits, so the legends and cutouts stay consistent from top to bottom.

One last honest note. A breaker protects the circuit, but it doesn't sort out the rest of your shore power setup. It doesn't replace a galvanic isolator or an isolation transformer, and it won't separate neutral from ground for you. Think of it as the main safety switch, then build the rest of the system around it. We're happy to help you sort out what else belongs on that panel. Just reach out with your boat's setup and we'll point you the right way.

Key Features

  • 50A AC rating, so it fits 50 amp shore power mains on mid-size and larger boats.
  • Triple pole design, opens both hot lines and the neutral together for 240 volt AC main use.
  • 120V AC / 240V AC maximum voltage rating, covering standard shore power systems.
  • Magnetic hydraulic trip free design, so the handle can't be held ON against a fault.
  • 5,000 amp interrupt capacity, which meets the ABYC requirement for 120/240 volt, 50 amp main protection.
  • 1/4-20 tin-plated brass terminal studs for a solid, corrosion resistant connection.
  • Flat rocker actuator sits flush in the ON position for a clean panel look.
  • Operating range of -40 deg C to 85 deg C, ready for cold and hot engine spaces.
  • 10,000 switching cycles rating, built to last through years of use.
  • 6-32 stainless steel mounting screws, so mounting hardware won't rust out.

Why Buy from NVN Marine

  • Authorized Blue Sea Systems reseller, full manufacturer warranty
  • NMEA member and ABYC certified, advice from real boat techs
  • Same-day shipping before 3 PM ET on in-stock items
  • NY headquarters and Fort Lauderdale flagship retail store
NVN Marine — 11 W State Road 84, Fort Lauderdale, FL 33315 Available for pickup at our Fort Lauderdale store (Next-Day) $138.99
03 · The numbers

Technical specifications

Title Blue Sea C-Series Flat Rocker Circuit Breaker Triple Pole 50A AC
Brand Blue Sea Systems
Manufacturer Part Number 7565-BSS
UPC 632085075651
Amperage 50A AC
Actuator Style Flat Rocker
Poles 3
Maximum Voltage 120V AC / 240V AC
Circuit Breaker Type Magnetic Hydraulic - trip free
Terminal Stud 1/4-20 Tin-Plated Brass
Terminal Stud Torque 35 in-lb (3.95 Nm)
Interrupt Capacity 5000A @ 48V DC
Minimum Operating Temperature -40 deg C
Maximum Operating Temperature 85 deg C
Mounting Screw 6-32 Stainless Steel
Mounting Screw Torque 6 in-lb (0.68 Nm)
Switching Cycles 10000
Weight 0.93lb (0.42 kg)
04 · Before you buy

Frequently asked questions

What does triple pole mean on this circuit breaker?

It means the breaker has three poles that all open together. On a 240 volt AC system that lets one breaker switch both lines (the hots) and the neutral. If any one pole trips, the breaker trips all poles.

Can I use this as a 240 volt AC main breaker?

Yes. Blue Sea Systems says the triple pole version can be used as a 240 volt AC main circuit breaker to switch both lines (hots) and neutral. The double pole version is the one for a 120 volt AC main.

What is the interrupt capacity?

It's rated 5,000 amps. That's the interrupt capacity needed to meet ABYC requirements for 120/240 volt, 50 amp main protection.

What does trip free mean?

Trip free means the handle can't be held ON during a fault current condition. If the breaker senses a fault, it opens even if you're holding the handle in the ON position.

How do I reset it after it trips?

Move the handle fully to OFF, then back to ON. A trip free breaker won't close until you do that. Many people assume a tripped breaker is broken, but it's working as designed.

What size terminal studs and torque does it use?

The terminal studs are 1/4-20 tin-plated brass. The terminal stud torque is 35 in-lb (3.95 Nm). Use a proper torque driver for the connection.

What are the mounting screw size and torque?

Mounting uses 6-32 stainless steel screws, torqued to 6 in-lb (0.68 Nm). Go light on those screws since the body is small.

What temperatures can it handle?

The operating temperature range is -40 deg C to 85 deg C, according to the manufacturer specifications.

Is this breaker AC or DC rated?

It's rated 50A AC, at 120V AC and 240V AC maximum voltage. Don't use it where a DC rated breaker is needed, and don't swap a DC breaker in for it on shore power.

How many times can it be switched?

It's rated for 10,000 switching cycles.

Does it need a flat rocker panel cutout?

Yes. It's a flat rocker style actuator, so your panel needs a flat rocker cutout. Confirm your panel before ordering if you're replacing a different style of breaker.