Victron Energy

Victron Centaur Charger - 12 VDC - 80AMP - 3-Bank - 120-240 VAC

SKU: 82832 · UPC: 8719076021520 · MPN: CCH012080000
4.7 · 0 reviews
Authorized dealer Free shipping15% off
$930.75
$1,095.00Save $164.25
or 4 payments of $232.68 with Affirm
Low stock — 1 left — Ships today
SAME-DAY SHIPPING · 14:23 EST
Order in time, ships today
Ships from your nearest warehouse. UPS Ground 2–4 business days.
Free shipping
Orders $500 or more
Free returns
Within 30 days
Same day shipping
Order before 3 PM (EST)
Ask anything
We're here to help
$930.75
02 · Overview

Victron Centaur Charger - 12 VDC - 80AMP - 3-Bank - 120-240 VAC — Product description

Victron Centaur Charger - 12 VDC - 80AMP - 3-Bank Marine Battery Charger

Professional-Grade Multi-Bank Charging for Serious Marine Applications

The Victron Centaur CCH012080000 delivers uncompromising performance for marine electrical systems demanding reliable, multi-bank battery charging. This professional-grade 80-amp charger simultaneously charges three separate 12V battery banks while withstanding the harshest marine environments through robust aluminum construction and advanced corrosion protection.

Engineered for worldwide compatibility with auto-ranging 90-265VAC input, this charger maintains full output power across the entire voltage range - a critical advantage over competitors that compromise performance at voltage extremes. Whether powering house batteries, engine start banks, or bow thruster systems, the Centaur ensures optimal charging performance in any configuration.

Marine-Engineered Features

Triple-Bank Independent Charging

Three completely isolated outputs each capable of delivering the full 80-amp capacity. Simultaneously charge house batteries, start battery, and auxiliary systems without cross-interference or voltage drop between banks.

Professional Three-Stage Charging

Advanced bulk-absorption-float charging algorithm with automatic temperature compensation (-2mV/°C per cell) ensures complete charging cycles. DIP switch selection optimizes charge profiles for flooded lead-acid, AGM, or gel batteries.

Marine Environment Protection

Aluminum epoxy powder-coated housing with integrated drip shield and stainless steel mounting hardware. Acrylic-coated circuit boards provide maximum corrosion resistance against salt air and humidity.

Universal Input Compatibility

Auto-ranging 90-265VAC input (50/60Hz) maintains full power output worldwide. Also accepts 90-400VDC input for diesel-electric vessel applications or DC-to-DC charging scenarios.

Technical Specifications

Model Number: CCH012080000
Output Voltage: 12V DC
Output Current: 80 Amps (per bank)
Charging Banks: 3 Isolated Outputs
AC Input Range: 90-265V AC, 50/60Hz
DC Input Range: 90-400V DC
UPC Code: 8719076021520
Manufacturer: Victron Energy

Advanced Charging Technology

Intelligent Three-Stage Process

  • Bulk Stage: Maximum current delivery until batteries reach 70% charge acceptance
  • Absorption Stage: Four-hour timer ensures complete charging without overcharge
  • Float Stage: Maintains batteries at optimal voltage for long-term storage

Temperature Compensation

Internal temperature sensor automatically adjusts charging voltage at -2mV/°C (-1mV/°F) per cell, preventing overcharging in hot conditions and ensuring adequate charging in cold environments.

Battery Chemistry Optimization

Selectable charge profiles via DIP switch accommodate flooded lead-acid, AGM, and gel batteries with manufacturer-recommended voltage settings for maximum battery life.

Installation & Compatibility

Mounting Requirements

  • Marine-grade aluminum construction with stainless steel mounting hardware
  • Integrated drip shield protects against moisture ingress
  • Requires adequate ventilation for thermal management
  • Temperature sensors prevent overheating with automatic current reduction

System Integration

  • Compatible with all 12V marine battery systems
  • Ideal for house/start/thruster battery configurations
  • Analog output current meter for monitoring charge status
  • Works as AC-DC or DC-DC converter in diesel-electric systems

Compliance & Certifications

  • CE Marking: Compliant for European marine applications
  • UL Listed: Approved for United States installations
  • ISO 9001: Quality management system certification
  • Russian River Boat Register: Commercial vessel approval
  • RoHS Compliant: Environmentally responsible manufacturing

Marine Applications

  • Cruising sailboats with house/start battery separation
  • Motor yachts requiring multiple battery bank management
  • Commercial vessels with bow thruster systems
  • Diesel-electric propulsion system DC-DC conversion
  • Marina dock-side battery maintenance and conditioning
  • Emergency backup power system charging

Warranty & Support

Backed by Victron Energy's comprehensive 5-year limited warranty, the Centaur Charger represents a long-term investment in reliable marine power management. Professional installation recommended for optimal performance and warranty compliance.

Important: Contact your authorized Victron dealer for returns, repairs, or technical support. Professional marine electrician installation ensures compliance with ABYC standards and optimal system performance.

Frequently Asked Questions

Can this charger handle different battery types on separate banks?

No, the DIP switch settings apply to all three banks simultaneously. All connected batteries should be the same chemistry (flooded, AGM, or gel) for optimal performance. For mixed battery types, consider separate single-bank chargers.

What size batteries can this 80-amp charger handle?

The 80-amp output is suitable for battery banks from 200Ah to 800Ah capacity. For optimal charging, battery bank capacity should be 2.5 to 10 times the charger output rating. Larger banks will charge more slowly but safely.

Is this charger suitable for lithium batteries?

The Centaur is designed for lead-acid chemistry batteries (flooded, AGM, gel). For lithium battery applications, consider Victron's Phoenix Smart or Blue Smart chargers specifically engineered for lithium charging profiles.

Can I use this charger with solar panels or wind generators?

The Centaur works alongside other charging sources. However, ensure proper isolation to prevent interference between charging systems. Consider a Victron Battery Monitor to track total system performance with multiple charging sources.

What maintenance does this charger require?

Minimal maintenance required. Periodically inspect mounting hardware for corrosion, ensure adequate ventilation around the unit, and verify connection tightness. The acrylic-coated circuit boards resist corrosion in marine environments.

Model CCH012080000 - Professional marine battery charging solution

Centaur Charger - 12 VDC - 80AMP - 3-Bank - 120-240 VAC

Features:

  • Quality without compromise -  Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.
  • Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation) All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz. 
  • The chargers also accept a 90-400 V DC supply. 
  • Three outputs that each can supply the full output current Three isolated outputs to simultaneously charge 3 battery banks Each output is capable to supply the full rated current. 
  • Three-stage charging, with temperature compensation The Centaur charges at bulk rate until the output has reduced to 70% of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per cell. A DIP switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM batteries

Warranty Info

Please contact your dealer for any returns, repairs or support issues related to this product.

"Quality without compromise. Aluminum epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation) All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz. Three isolated outputs to simultaneously charge 3 battery banks. Each output is capable to supply the full rated current. Three-stage charging, with temperature compensation. The Centaur charges at bulk rate until the output has reduced to 70% of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with - 2 mV\/C (- 1 mV\/F) per cell. A DIP switch is available to select the optimum charge\/float voltages for Flooded Lead-acid, Gel or AGM batteries."
SKU: NVN-82832
MPN: CCH012080000
UPC: 8719076021520
03 · The numbers

Technical specifications

BrandVictron Energy
ModelVictron Centaur Charger - 12 VDC - 80AMP - 3-Bank - 120-240 VAC
SKU / MFR#82832

Set product metafields under specs.* to populate this table.

04 · Before you buy

Frequently asked questions

No questions yet. Got one? Drop us a line.

05 · Customer voices

Customer reviews